Data Center Location: Power, Cooling, Network

Card No. 06·6205 · Updated · Standard formula, shown below

Choosing a data center location is a balancing act between power availability, cooling efficiency, and network connectivity. This guide walks you through the key factors to evaluate so you can pick a site that meets your performance, cost, and reliability needs. You’ll learn what to check, what questions to ask, and how to avoid common pitfalls.

What You’ll Need

  • Your projected IT load in kilowatts (kW) – total power draw of all servers, storage, and network gear.
  • Your latency requirements – maximum acceptable round-trip time to your users or core applications.
  • A budget range for monthly colocation or build costs.
  • A list of your availability needs (e.g., 99.9% vs. 99.99% uptime).
  • Access to utility rate maps or quotes from local power providers.
  • Climate data for the region (average temperatures, humidity, risk of natural disasters).

Step-by-Step

  1. Define your power requirements. Calculate your total IT load in kW, then add overhead for cooling, lighting, and UPS losses (typically 1.5–2.0× your IT load). This gives you your facility power requirement. For example, a 100 kW IT load might need a 200 kW facility. Also note your power density per rack (kW/rack) – high-density deployments need more cooling and power per square foot.
  2. Check utility power availability and reliability. Contact the local utility or use public data to confirm that the grid can supply your required capacity. Look at the region’s grid reliability history – frequency of outages, voltage fluctuations, and average restoration times. Some areas have constrained grids where new large loads face long interconnection queues or require expensive upgrades. Also check if the site has redundant utility feeds from different substations.
  3. Evaluate renewable energy and cost incentives. If sustainability is a priority, check the local grid’s renewable mix and whether you can purchase green power. Some regions offer tax breaks or lower rates for large energy users. Compare the cost per kWh across candidate locations – this can vary by 2–3× between states or countries. Remember that power is often the largest operating expense for a data center.
  4. Assess cooling options based on climate. For air-cooled facilities, look at the region’s average annual temperature and humidity. Cooler climates allow more free cooling (using outside air) which reduces energy use. For example, a site in Oregon or Finland can use free cooling most of the year, while a site in Arizona or Singapore relies heavily on chillers. Also consider water availability – evaporative cooling needs significant water, so arid regions may have water scarcity issues.
  5. Consider cooling technology alternatives. If the climate is hot, look at liquid cooling (direct-to-chip or immersion) which is more efficient for high-density racks. This may allow you to build in warmer locations without excessive cooling costs. Check if the facility has sufficient floor space and plumbing for liquid cooling retrofits.
  6. Map network connectivity. List the carriers and internet exchanges you need (e.g., Tier 1 ISPs, cloud providers, major peering points). Check which ones have a physical presence in the candidate data centers. Use tools like PeeringDB or ask the facility for a list of carriers. Also measure latency to your key user locations – use ping tests or network monitoring tools. A site in a major hub (e.g., Ashburn, London, Singapore) will have low latency to many destinations but may be more expensive.
  7. Evaluate network redundancy and diversity. Ensure the facility has multiple fiber entry points from different directions, so a single fiber cut doesn’t take you offline. Ask about cross-connect costs and whether you can easily connect to multiple carriers. Also check if the building has redundant network infrastructure (e.g., dual routers, diverse paths).
  8. Review physical security and environmental risks. Check the site’s location relative to flood zones, earthquake faults, tornado alleys, and wildfire areas. Look at the building’s construction – concrete vs. metal, roof design, and whether it has backup generators and fuel storage. Review security measures like 24/7 monitoring, biometric access, and CCTV.
  9. Analyze total cost of ownership (TCO). Create a spreadsheet comparing power costs, cooling costs (based on climate), network costs (cross-connects, bandwidth), real estate, and taxes. Include one-time build-out costs and ongoing operational costs. A cheaper power rate may be offset by higher cooling costs in a hot climate or by expensive network connectivity in a remote area.
  10. Visit the site and validate. If possible, visit the data center to verify power capacity, cooling systems, and network presence. Ask for a walkthrough of the mechanical and electrical rooms. Check the actual power usage effectiveness (PUE) – the ratio of total facility energy to IT energy. A good PUE is 1.2–1.5, but lower is better.
  11. Plan for future growth. Ensure the site can scale with you – check if there is extra power capacity, space for additional racks, and ability to add more network connections. Ask about the facility’s expansion plans and whether they have reserved capacity.

Common Mistakes

  • Underestimating power needs. Forgetting to include cooling and overhead can lead to insufficient capacity. Always add a safety margin of 20–30%.
  • Ignoring local climate. Choosing a site in a hot, humid area without proper cooling design will spike energy costs and increase failure risk.
  • Overlooking network diversity. Assuming one carrier is enough – a single point of failure can cause outages.
  • Focusing only on power price. A low kWh rate might be offset by high network costs or poor reliability.
  • Not checking for hidden fees. Cross-connect charges, power metering fees, and maintenance costs can add up.

Tips

  • Use a data center location matrix to score each candidate on power, cooling, network, cost, and risk.
  • Talk to existing tenants or customers of the facility to get real-world feedback.
  • Check the facility’s uptime record and ask for a service level agreement (SLA) with financial penalties for downtime.
  • Consider using a cloud provider’s region as a guide – they have already done extensive location analysis.
  • For high-availability workloads, look for a metro area with multiple independent data centers so you can build active-active redundancy.

Troubleshooting

  • If you can’t get the power capacity you need, ask the facility about their future expansion plans or look for a different site. Some facilities have reserved power for new customers.
  • If network latency is too high, consider a hybrid approach – place latency-sensitive workloads in a hub, and less sensitive ones in a cheaper location.
  • If cooling costs are higher than expected, re-evaluate your rack density – spreading loads out may reduce hot spots. Also consider liquid cooling for high-density racks.
  • If the utility grid is unreliable, ensure the facility has robust generators and fuel storage. Ask about their fuel contracts and how long they can run on backup power.
  • If you’re facing budget overruns, renegotiate the power rate or look for a facility with lower cross-connect fees. Sometimes a slightly less optimal location can save significant money.

Frequently Asked Questions

What is the most important factor when choosing a data center location?

Power availability and reliability are usually the most critical because without power, nothing runs. Network connectivity is a close second, especially for latency-sensitive applications.

How much power do I need for my servers?

Start with your IT load in kW, then multiply by 1.5 to 2.0 to account for cooling and overhead. For example, a 50 kW IT load might need a 100 kW facility.

What is PUE and why does it matter?

Power Usage Effectiveness (PUE) is the ratio of total facility energy to IT energy. A PUE of 1.5 means for every 1 kW of IT power, the facility uses 0.5 kW extra for cooling and other overhead. Lower PUE means better efficiency and lower costs.

Can I use free cooling in a warm climate?

Free cooling is most effective in cool climates, but some systems use evaporative cooling that works in warm, dry areas. In hot, humid climates, you’ll rely on chillers, which increase energy use.

How do I check network connectivity in a data center?

Ask the facility for a list of carriers and internet exchanges on-site. You can also use tools like PeeringDB to see which networks are present. Test latency by pinging servers in the facility from your location.

What is the difference between Tier 1, 2, 3, and 4 data centers?

Tier levels indicate redundancy. Tier 1 has no redundancy, Tier 2 has some redundant components, Tier 3 has N+1 redundancy (one extra component), and Tier 4 has 2N+1 (fully redundant). Higher tiers are more reliable but cost more.