Choosing a colocation provider is a long-term commitment that affects your uptime, security, and budget. This guide walks you through the key factors to assess when evaluating a data center operator, from physical infrastructure to contract terms, so you can make an informed decision that aligns with your business needs.
What You’ll Need
- A list of your current and future IT requirements (power, cooling, space, bandwidth)
- A budget range for monthly recurring costs and setup fees
- Compliance requirements (e.g., GDPR, HIPAA, PCI-DSS) if applicable
- A checklist of questions to ask during site tours and sales calls
- Time to review contracts and SLAs (service level agreements) with legal or procurement
Step-by-Step
- Define your requirements. Before looking at any provider, know your power density per rack (kW), total space needed, network throughput, and redundancy level (N, N+1, 2N). Also project growth over the next 3-5 years so you don’t outgrow the facility.
- Shortlist operators based on location. Proximity to your office or users reduces latency, but also consider disaster recovery: a facility in a different flood zone or seismic region than your primary site is often wise. Check for local risks like flood plains, fault lines, or airports.
- Review financial stability. Ask for annual reports or credit ratings (if public). A colocation provider that goes bankrupt can leave you scrambling. Look for signs of consistent investment in the facility.
- Inspect the physical infrastructure. Schedule a site tour. Look for:
- Power redundancy: Does each UPS have backup? Are there multiple utility feeds? What is the generator fuel capacity and refueling contract?
- Cooling: Are hot/cold aisles separated? What happens if a CRAC unit fails? Is the cooling capacity adequate for the deployed density?
- Physical security: Man traps, biometrics, 24/7 monitoring, camera retention policy, and visitor logs.
- Evaluate network and connectivity. Ask about carrier diversity (number of carriers in the building), cross-connect options, and whether the facility has a meet-me room. Check if they offer remote hands and what the response time is.
- Examine the SLA. Read the service level agreement carefully. Look for uptime guarantees (typically 99.9% or higher), power availability credits, and what happens if they fail to meet the SLA. Ensure the SLA covers both infrastructure and support response times.
- Test customer support. Call their support line before signing. How quickly do they answer? Ask a technical question and gauge their expertise. Good support is critical during outages.
- Check compliance certifications. Depending on your industry, you may need SOC 2, ISO 27001, PCI-DSS, or HIPAA compliance. Ask for copies of their latest audit reports. Don’t just take their word—verify the scope.
- Talk to existing customers. Ask the provider for references. Contact those customers and ask about uptime history, support quality, and any billing disputes. If the provider hesitates to provide references, that’s a red flag.
- Review contract terms. Look for exit fees, minimum term length, and what happens to your equipment if you leave. Ensure the contract allows for growth (e.g., additional space at a pre-agreed rate).
- Perform a proof of concept. If possible, start with a small deployment (e.g., a single rack) to test the operational experience before committing to a large footprint.
Common Mistakes
- Focusing only on price. The cheapest provider may have poor redundancy or support, costing you more in downtime.
- Not verifying power density. Your racks may need more than the standard 2-5 kW per rack. Ensure the provider can deliver higher density if needed.
- Ignoring the SLA details. Some SLAs only credit your bill, not compensate for lost business. Read the fine print.
- Skipping the site tour. Photos and brochures can be misleading. Always visit the facility in person.
- Not checking the provider’s financial health. A struggling provider may cut corners on maintenance.
Tips
- Ask about the facility’s power usage effectiveness (PUE). A lower PUE (e.g., 1.2 vs 1.5) means more efficient cooling and potentially lower costs passed on to you.
- Check the provider’s maintenance history. Ask how many unplanned outages they’ve had in the past year and what the root causes were.
- Consider the provider’s expansion plans. If they are building out additional capacity, that’s a good sign. If they are at 95% capacity, they may be out of space soon.
- Review the remote hands policy. Know the hourly rate and response time for basic tasks like reboots or cable changes.
- Look at the facility’s fire suppression system. Pre-action or inert gas systems are safer for electronics than standard sprinklers.
Troubleshooting
If the evaluation doesn’t go as planned, here’s what to do:
- Provider is evasive about financials or references. That’s a red flag. Move on to the next candidate.
- You discover a hidden fee after signing. Before signing, ask for a complete list of all charges: power, bandwidth, cross-connects, remote hands, and any administrative fees. If something appears later, escalate to the account manager and review the contract.
- The site tour reveals unsafe conditions. Trust your instincts. If you see poor housekeeping, exposed cables, or unsecured doors, the provider may not maintain the facility properly.
- You can’t get a clear answer on power redundancy. Ask to see the one-line diagram of the electrical system. If they can’t provide it, they may not have a solid design.
- The provider’s SLA seems too good to be true. Compare with industry standards. If they guarantee 100% uptime, that’s unrealistic—ask how they define uptime and what exclusions apply.
Frequently Asked Questions
What is the difference between colocation and cloud hosting?
Colocation means you own the hardware and rent space, power, and cooling. Cloud hosting means you rent virtualized resources from a provider. Colocation gives you physical control and is often more cost-effective at scale, while cloud offers flexibility and no hardware management.
How much does colocation cost on average?
Costs vary widely by region and power density. A typical half-rack with 2-3 kW might cost $500-$1,500 per month, but this is a rough estimate. Always get detailed quotes from multiple providers.
What is N+1 redundancy?
N+1 means that if you have N components required for operation (e.g., UPS modules), you have one additional backup. So if one fails, the system continues to run without interruption. It’s a common standard for critical infrastructure.
Can I move my equipment out easily if I’m not satisfied?
Yes, but check the contract for exit fees and notice periods. Some providers require 30-90 days notice. Also, consider the cost of moving hardware and potential downtime during migration.
Do I need to visit the data center in person?
Yes, absolutely. A virtual tour is not enough. Visiting allows you to see the physical security, cleanliness, and overall operations. It also gives you a chance to talk to staff and gauge their professionalism.
What should I look for in the SLA’s uptime guarantee?
Look for a specific percentage (e.g., 99.9% power uptime) and what remedies are provided if they fail. Also check what is excluded (e.g., scheduled maintenance) and how credits are calculated.
Related
Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.
More cards in this drawer
- Data Center Security: Encryption, Backups, Access
- Best Mini PCs for Gaming: Top Picks
- Phone Buttons: Clever Ways to Use Them
- Resonance Solstice Codes: What They Are
- Peak Evolution Codes: What They Are & How to Use132
- Google Smart Locks: What They Are & How They Work