How to Measure Dielectric Loss and Capacitor Leakage

Card No. 06·60590 · Updated · Standard formula, shown below

Measuring dielectric loss and leakage helps you assess whether a capacitor dissipates excessive energy or passes too much direct current. You will need an LCR meter or impedance analyzer for loss, and a current meter or electrometer with a controlled DC supply for leakage; first disconnect the capacitor from its circuit, discharge it safely, and check its rated voltage and polarity.

What You’ll Need

  • An LCR meter or impedance analyzer that can display dissipation factor (D or tan δ), or capacitance and equivalent series resistance (ESR).
  • A DC power supply with adjustable voltage and current limiting, plus a digital multimeter with a suitable low-current range. For very small leakage currents, use an electrometer or picoammeter.
  • Insulated leads, a resistor suitable for discharging the capacitor, and a timer.
  • The capacitor datasheet, including rated voltage, test conditions, polarity, and specified leakage or loss limits.
  • Eye protection and a safe, nonconductive work area. High-voltage capacitors can retain dangerous charge after disconnection.

Step-by-Step

  1. Identify the capacitor and its test limits. Record its capacitance, rated voltage, type, polarity, and temperature rating. Find the manufacturer’s test frequency and voltage for dielectric loss, and its leakage-current test voltage and specified measurement time. Limits vary widely by capacitor type; do not substitute a generic pass/fail threshold.
  2. Isolate and discharge it. Remove the capacitor from the circuit when practical; parallel components can distort both readings. Disconnect power, verify the circuit is de-energized, and discharge the capacitor through a resistor rated for the possible voltage and energy. Do not short the terminals with a tool. Verify near-zero voltage across the terminals with a meter before handling, then leave the resistor connected briefly if the capacitor may recover some voltage.
  3. Inspect and prepare. Do not test a bulged, cracked, leaking, burnt, or badly corroded capacitor as if it were safe to reuse. Clean and dry the terminals if needed. For polarized capacitors, mark the positive and negative terminals and maintain correct polarity throughout the DC test. Let the part reach the temperature specified by its datasheet; temperature changes leakage substantially.
  4. Set up the loss measurement. With the capacitor discharged, connect it to the LCR meter or analyzer according to the instrument instructions. Select the datasheet’s test frequency and signal level. If the datasheet gives no condition, choose a frequency appropriate to the capacitor’s intended use and record it; a result is meaningful only with its test conditions. Use a suitable fixture, short or compensate the leads as the instrument requires, and avoid touching exposed measurement contacts.
  5. Read and record dielectric loss. Measure dissipation factor, displayed as D or tan δ, and record capacitance, frequency, test level, and temperature. If the meter reports ESR instead, record that and the frequency. For a simple series-equivalent model, tan δ = 2πfC·ESR, where f is in hertz, C in farads, and ESR in ohms. This conversion is only valid when the instrument’s model and conditions are appropriate; prefer a direct D reading when available.
  6. Prepare the leakage-current circuit. Set the supply to zero before connecting. Put the meter in series with the capacitor and supply, selecting a current range that can tolerate the expected current. A series current-limiting resistor is a useful extra safeguard, but it affects the voltage across the capacitor: measure that voltage at the capacitor terminals. Check lead polarity and meter jack placement carefully. Never connect a current meter directly across the supply.
  7. Apply the specified DC test voltage. Start at zero and raise the voltage gradually to the datasheet test voltage, never exceeding the capacitor’s rated voltage or any lower specified limit. Observe polarity. Use current limiting, keep hands clear of exposed conductors, and stop if the capacitor heats, swells, vents, or makes unusual sounds. Some capacitors draw a large charging current at first; do not mistake this transient for steady leakage.
  8. Wait, then measure leakage. Start timing when the specified test voltage is reached. Read current at the manufacturer’s stated time, since absorption and charging behavior can make early readings much higher. If no time is given, record readings at consistent intervals and report the elapsed time rather than claiming a datasheet pass. Check that the voltage remains at the capacitor terminals while taking the reading.
  9. Finish safely and compare results. Reduce the supply to zero, disconnect it, and discharge the capacitor through the resistor. Verify the voltage is near zero before touching leads. Compare loss and leakage only with limits for the same capacitor type, temperature, frequency, applied voltage, and test duration. Record instrument, range, conditions, and readings for repeatability.

Common Mistakes

  • Measuring in-circuit, where other components create parallel paths or affect the LCR reading.
  • Comparing readings taken at different frequencies, voltages, temperatures, or settling times.
  • Calling the initial charging current leakage. Wait for the prescribed interval and distinguish a decaying transient from steady current.
  • Using the wrong meter jack or connecting an ammeter across a voltage source, which can damage the meter or create a short circuit.
  • Reversing a polarized capacitor or exceeding its rated voltage. Either can cause damage or hazardous failure.
  • Treating ESR and dielectric loss as interchangeable without considering frequency and the instrument’s equivalent-circuit model.

Tips

  • Use the same fixture, lead arrangement, frequency, temperature, and wait time for before-and-after or comparison measurements.
  • For tiny leakage currents, clean and dry fixtures, use guarded connections if available, and allow the instrument and capacitor to settle. Fingerprints and moisture can create leakage paths.
  • Check the meter’s burden voltage and current-range resolution. A meter that drops too much voltage in series may prevent the capacitor from receiving the intended test voltage.
  • Keep a written record of measured values and test conditions. A number without those conditions is difficult to interpret or reproduce.

Troubleshooting

Current stays high: Confirm the capacitor is isolated, polarity is correct, and the test voltage is not above the specified value. Wait the full measurement interval. If current does not settle, stop the test and compare against the datasheet; a damaged or unsuitable capacitor may be responsible.

Leakage reading jumps or drifts: Check loose connections, meter range, battery or supply stability, surface contamination, and moisture. Verify voltage directly across the capacitor and repeat after the fixture is clean and dry.

LCR readings vary: Recheck frequency, test level, contact quality, and lead compensation. Confirm the capacitor is fully discharged before measuring and that it is not still connected to other components.

The meter shows overload or nearly zero current: Select an appropriate range and check the meter’s input and fuse. For current below a multimeter’s resolution, use an electrometer or a suitable high-value resistor method, accounting for the resistor’s tolerance and the actual capacitor voltage. Do not improvise a high-voltage setup without appropriate equipment and training.

Frequently Asked Questions

What does dielectric loss measure?
It describes energy dissipated in the capacitor’s dielectric under an alternating signal. Dissipation factor, D or tan δ, is commonly used; lower values generally mean less loss under the stated test conditions.

Is leakage current the same as dielectric loss?
No. Leakage is direct current through or across the insulation under DC voltage. Dielectric loss concerns energy dissipation under AC. A capacitor can perform differently on these two tests.

Can I measure leakage with a regular multimeter?
Sometimes, if leakage is within the meter’s current range and resolution. Small currents may require an electrometer or picoammeter. The meter must be connected in series, and the capacitor voltage must be controlled and verified.

How long should I wait before recording leakage?
Use the test time in the capacitor datasheet. If none is specified, record the elapsed time and readings consistently; do not compare them with a limit intended for a different test duration.

Can I test the capacitor without removing it?
For reliable results, isolate at least one terminal. In-circuit paths can affect readings, and a connected circuit may retain hazardous voltage. Disconnect and discharge before testing.

What result means the capacitor has failed?
Use the manufacturer’s limit for the specific part and test conditions. Physical damage, unstable readings, or values outside that limit are reasons to remove it from service rather than infer a universal threshold.