An ohms-to-temperature calculator converts a resistance reading (in ohms) into a temperature value, typically for platinum resistance thermometers (PRT/PT100) or thermistors. You enter the measured resistance and the sensor type, and the calculator returns the equivalent temperature in °C or °F using the standard calibration equation.
Formula
For a platinum RTD with a linear alpha coefficient, the relationship between resistance and temperature is:
T = (Rt / R0 − 1) / α
Where:
- Rt = measured resistance at temperature T (ohms)
- R0 = nominal resistance at 0°C (ohms) – usually 100 Ω for PT100, 1000 Ω for PT1000
- α = temperature coefficient of resistance (1/°C) – typically 0.00385 for European standard, 0.00392 for American standard
- T = temperature in °C
This linear approximation works well from about −50°C to +150°C. For wider ranges, the Callendar–Van Dusen equation adds quadratic and cubic terms for better accuracy.
Worked Example
Using the default values: Rt = 138.5 Ω, R0 = 100 Ω, α = 0.00385.
- Compute the ratio: 138.5 / 100 = 1.385
- Subtract 1: 1.385 − 1 = 0.385
- Divide by α: 0.385 / 0.00385 = 100.00
The calculator shows 100.00°C. This matches the known PT100 table value for 100°C.
Why Resistance Changes with Temperature
In metals like platinum, higher temperature increases lattice vibrations, which scatter electrons and raise resistance. This effect is predictable and repeatable, which is why platinum is the standard for precision temperature sensing. Thermistors (usually metal oxides) show a much larger, but non-linear, decrease in resistance as temperature rises – they use a different equation.
The linear model above is a simplification of the more accurate polynomial used in industrial RTDs. For a PT100 per IEC 60751, the temperature is often calculated from:
R(T) = R0(1 + A·T + B·T² + C·(T−100)·T³) (for T < 0°C)
But for most practical purposes in the −50 to +150°C range, the linear formula is within a fraction of a degree.
How to Choose the Right Sensor Type
Before using the calculator, identify your sensor:
- PT100 – 100 Ω at 0°C, most common in industry, good accuracy, needs a 3-wire or 4-wire connection to cancel lead resistance.
- PT1000 – 1000 Ω at 0°C, higher resistance reduces lead-wire errors, often used in HVAC and automotive.
- Thermistor (NTC) – resistance drops sharply with temperature, highly sensitive but non-linear; use a Steinhart–Hart equation instead.
Check your sensor’s datasheet for the exact alpha value. The European standard uses α = 0.00385; some older US sensors use 0.00392. Using the wrong alpha can cause errors of several degrees.
Common Problems and How to Avoid Them
Unit mix-ups are the most frequent error. If you measure resistance in kilohms, convert to ohms first (multiply by 1000). Also be aware of lead resistance: a 2-wire measurement adds the wire resistance to the sensor reading, which can be significant for PT100. For example, 10 meters of 0.5 mm² copper wire has about 0.35 Ω per conductor, giving a 0.7 Ω error – that translates to roughly 1.8°C.
Another issue is using the linear formula outside its valid range. At −200°C, the linear approximation can be off by more than 1°C. For cryogenic or high-temperature work, use the full Callendar–Van Dusen equation or a lookup table.
Finally, self-heating: the current used to measure resistance warms the sensor slightly. Keep the measuring current low (typically ≤1 mA for PT100) to minimize this error.
Comparison: RTD vs. Thermistor vs. Thermocouple
- RTD (PT100) – most accurate and stable, but slower response and more expensive. Range: −200 to +600°C.
- Thermistor – very sensitive, fast, cheap, but non-linear and limited to about −50 to +150°C.
- Thermocouple – wide range (−200 to +2000°C), rugged, but less accurate and requires cold-junction compensation.
If you are measuring with a thermocouple, an ohms-to-temperature calculator is not applicable – you need a voltage-to-temperature table.
Costs and Practical Considerations
PT100 sensors vary widely in price depending on accuracy class and probe construction. A basic thin-film PT100 can be a few dollars, while a laboratory-grade standard platinum resistance thermometer can cost hundreds. The calculator itself is free, but the sensor and a good readout (multimeter or transmitter) are the main costs. For most hobby and industrial uses, a standard PT100 with a 3-wire connection offers a good balance of price and performance.
Safety and Accuracy Tips
Always verify the sensor’s rated temperature range. Exceeding it can damage the sensor or give false readings. When measuring hot surfaces or liquids, use proper thermal contact – air gaps cause lag and error. For electrical safety, ensure the measuring circuit is isolated from mains voltage. If you need precise readings for a critical process, calibrate the sensor against a known reference at least at one point (ice bath for 0°C, boiling water for 100°C at sea level).
Frequently Asked Questions
What is the resistance of a PT100 at 100°C?
Using the standard α = 0.00385, the resistance is 138.5 ohms. That’s the default in the calculator, and it matches the IEC 60751 standard.
Can I use this calculator for thermistors?
No, not directly. Thermistors have a non-linear exponential relationship. Use the Steinhart–Hart equation or a manufacturer lookup table instead.
How do I convert °C to °F?
Multiply the Celsius temperature by 9/5 and add 32. For example, 100°C × 1.8 + 32 = 212°F.
Why does my multimeter show a different resistance than expected?
Check for lead resistance, poor connections, or self-heating. Also verify that the sensor is not damaged and that you are using the correct excitation current.
What is the difference between PT100 and PT1000?
PT100 has 100 ohms at 0°C, PT1000 has 1000 ohms. PT1000 is less sensitive to lead wire resistance but requires a more sensitive measurement circuit.
Is the linear formula accurate for all temperatures?
No. It is accurate to about ±0.5°C from −50 to +150°C. Outside that range, use the polynomial equation from the sensor’s standard.
Related
Formula used
in r | Resistance | ohms | 138.5 | 0 | 10000 in t0 | Nominal R at 0°C | ohms | 100 | 10 | 1000 in a | Alpha (1/°C) | - | 0.00385 | 0.003 | 0.004 out temp | Temperature | °C | (r / t0 - 1) / a | 2 out ratio | R/R0 | - | r / t0 | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.
More cards in this drawer
- Measuring Light Speed & Wavelength: How It Works
- Draco Race Blox Fruits: How to Get It
- ES File Explorer Tips & Tricks That Actually Work
- Remove Google FRP Lock on Oppo: Step-by-Step
- Forza Horizon 6: Unlock Legend Island & Earn Horizon Legend
- Clean Hair Dryer Filter: Improve Airflow