Part G water calculations refer to the UK Building Regulations Approved Document G, which sets minimum standards for the safe and efficient use of water in new dwellings. You input details about your planned fittings — baths, showers, taps, toilets, and washing machines — and the calculator works out the estimated total water use per person per day, which must not exceed 125 litres. It also checks hot water safety requirements, but the main numerical calculation is the water efficiency target.
Formula
The Part G water calculation is a simple sum of estimated daily water use from each fitting type, plus a fixed allowance for other uses (cooking, drinking, cleaning, outdoor taps). The standard formula is:
Total use (L/person/day) = (baths × bath capacity × 0.05) + (showers × shower flow × 11.2) + (washbasins × tap flow × 1.58) + (toilets × flush volume × 4.42) + 17.4
Where:
- Baths – number of baths in the dwelling
- Bath capacity – volume of water the bath holds when full, in litres (typically 150–180 L)
- Showers – number of shower units
- Shower flow – flow rate in litres per minute (typical 8–12 L/min)
- Washbasins – number of washbasins
- Tap flow – flow rate of basin taps in litres per minute (typical 4–6 L/min)
- Toilets – number of toilets
- Flush volume – volume per flush in litres (modern dual-flush averages 6 L, but can be 4.5 L)
- 17.4 – fixed allowance for kitchen sink, washing machine, and other uses (litres per person per day)
The coefficients (0.05, 11.2, 1.58, 4.42) come from assumptions about how often each fitting is used per day. For example, 0.05 means a bath is taken on average once every 20 days per person, while 4.42 flushes per person per day is the assumed toilet usage.
Worked Example
Using the default values from the calculator above (1 bath, 150 L capacity, 1 shower at 8 L/min, 2 washbasins at 6 L/min, 1 toilet at 6 L):
- Baths: 1 × 150 × 0.05 = 7.5 L
- Showers: 1 × 8 × 11.2 = 89.6 L
- Washbasins: 2 × 6 × 1.58 = 18.96 L
- Toilets: 1 × 6 × 4.42 = 26.52 L
- Fixed allowance: 17.4 L
Total = 7.5 + 89.6 + 18.96 + 26.52 + 17.4 = 159.98 L/person/day. This exceeds the 125 L limit, so you would need to reduce shower flow, bath size, or toilet flush volume to comply.
Background: Why Part G Exists
Approved Document G is part of the Building Regulations for England, covering hygiene, water efficiency, and hot water safety. The water efficiency requirement was introduced in 2010 to address water scarcity and reduce the environmental impact of new housing. The 125 L/person/day limit is a national standard that local authorities can tighten to 110 L in areas with serious water stress. The calculation is mandatory for new dwellings and some conversions, and it must be submitted with the building control application.
How to Choose Fittings
Selecting fittings is a balancing act between comfort, cost, and compliance. For showers, a flow rate of 8 L/min or less is typical for efficient models; aerated shower heads can reduce flow without sacrificing pressure feel. For toilets, dual-flush mechanisms with a 4.5 L full flush and 3 L reduced flush are common. Baths are the hardest to control because capacity is fixed by the tub size; a 170 L bath uses more water than a 150 L one, but the usage coefficient is low (0.05), so the impact is small. Basin taps with flow restrictors (5 L/min or less) help, and washing machines are not counted individually—they are included in the 17.4 L fixed allowance.
Common Mistakes and Misconceptions
A frequent error is forgetting to include all washbasins, or using the maximum bath capacity instead of the typical fill level (most people fill a bath to about two-thirds). Another misconception is that the 17.4 L allowance covers all kitchen and laundry use—it does, but it is fixed, so you cannot reduce it by choosing a water-efficient washing machine. People also confuse the Part G calculation with the Water Label scheme or with the older Part H (drainage) requirements. The Part G calculation is only about water consumption, not about drainage or rainwater harvesting.
How to Read the Result
The output is a single number: estimated litres per person per day. If it is 125 or below, the design passes. If above, you need to adjust fittings or add water-saving measures. The calculator also shows the remaining allowance (125 minus your total), which tells you how much headroom you have. A negative remaining allowance means you exceed the limit. Note that the calculation assumes a fixed number of occupants (usually based on the number of bedrooms), but the per-person figure is independent of occupancy, so you can compare designs directly.
Limitations of the Calculation
The Part G formula is a simplified model based on average usage patterns. It does not account for actual occupant behaviour, seasonal variations, or garden watering. It also assumes all showers are used at the stated flow rate, but in reality, people may use less or more. The fixed allowance of 17.4 L is an average and may not reflect a household with a large family or a high-end washing machine. Furthermore, the calculation does not include water used for outdoor purposes, which is why the allowance is fixed. For hot water safety, Part G also requires that hot water be stored at a minimum of 60°C and delivered at a maximum of 50°C to prevent scalding, but this is a separate check, not part of the water efficiency number.
Frequently Asked Questions
What does Part G water calculation actually measure?
It measures the estimated daily water consumption per person in a new dwelling, based on the number and type of sanitary fittings. The result is compared against the 125-litre limit to prove compliance with Building Regulations.
Do I need a Part G calculation for a house extension?
Usually no, unless the extension creates a new dwelling (e.g., a granny flat) or materially changes the water system. A simple bathroom addition to an existing home typically does not trigger a full Part G assessment, but you should confirm with your local building control.
Can I use a rainwater harvesting system to reduce my Part G number?
No, the Part G calculation only considers water supplied from the mains. Rainwater harvesting can reduce overall consumption, but it is not credited in the standard calculation. Some local authorities may offer credits for greywater systems, but this is not part of the national formula.
What happens if my calculation exceeds 125 litres?
You will need to modify your design—for example, by installing lower-flow shower heads or more efficient toilets—and resubmit the calculation. Building control will not approve the plans until the figure is at or below the limit.
Is the 125-litre limit the same everywhere in the UK?
No, it is the default for England. Wales, Scotland, and Northern Ireland have their own building regulations, though they are similar. Some local authorities in England can set a stricter limit of 110 litres in areas of water stress, so always check with your local planning department.
Does the calculation include external taps?
No, external taps are not included in the formula. The fixed 17.4 L allowance is meant to cover internal uses like kitchen and laundry, but not garden watering. If you add an external tap, it does not affect the Part G number, but it may be subject to other regulations like backflow prevention.
Related
Formula used
in baths | Number of baths | - | 1 | 0 | 10 in bath_cap | Bath capacity (litres) | L | 150 | 50 | 500 in showers | Number of showers | - | 1 | 0 | 10 in shower_flow | Shower flow rate (L/min) | L/min | 8 | 2 | 30 in washbasins | Number of washbasins | - | 2 | 0 | 10 in taps_flow | Basin tap flow (L/min) | L/min | 6 | 1 | 20 in toilets | Number of toilets | - | 1 | 0 | 10 in toilet_flush | Toilet flush volume (L) | L | 6 | 2 | 15 out total | Total water use per person per day | L/person/day | (baths * bath_cap * 0.05) + (showers * shower_flow * 11.2) + (washbasins * taps_flow * 1.58) + (toilets * toilet_flush * 4.42) + 17.4 | 1 out allowance | Remaining allowance | L/person/day | 125 - ((baths * bath_cap * 0.05) + (showers * shower_flow * 11.2) + (washbasins * taps_flow * 1.58) + (toilets * toilet_flush * 4.42) + 17.4) | 1
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.
More cards in this drawer
- Measuring Light Speed & Wavelength: How It Works
- Draco Race Blox Fruits: How to Get It
- ES File Explorer Tips & Tricks That Actually Work
- Remove Google FRP Lock on Oppo: Step-by-Step
- Forza Horizon 6: Unlock Legend Island & Earn Horizon Legend
- Clean Hair Dryer Filter: Improve Airflow