Part G Water Calculator: How to Use It

Card No. 06·1205 · Updated · Standard formula, shown below

The calculator on this card is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

The Part G water calculator works out the minimum hot or cold water flow rate and pipe size you need for a dwelling in England, based on the number of bathrooms and the Building Regulations Part G formula. You enter the number of bathrooms, the type of property, and the number of outlets, and it returns the required flow rate in litres per minute and a recommended pipe diameter. This page explains the formula behind the calculator, how to read the results, and how to apply them to real plumbing designs.

Formula

The Part G water calculator uses a simplified version of the methodology in Approved Document G of the Building Regulations (England). The core requirement is that a dwelling must have a minimum flow rate of water at the kitchen sink, usually taken as 8 litres per minute, and that the pipework must be sized to deliver that flow under normal operating conditions. For a whole house, the formula commonly used is:

Required flow (L/min) = (number of bathrooms × 8) + (number of bedrooms × 4)

For flats, a factor of 0.8 is applied to the total to reflect lower simultaneous demand. In the calculator, the property type selector sets this factor: 1 for a house, 0.8 for a flat. The output is the minimum flow rate that the incoming main must supply, assuming all outlets are not used at once. The pipe size recommendation is a practical guide: 15 mm for flows up to 20 L/min, 22 mm for 20–30 L/min, and 28 mm for above 30 L/min. These are typical copper or plastic pipe sizes used in domestic installations.

Worked Example

Take a 3-bedroom house with 2 bathrooms. Enter 2 for bathrooms and 3 for bedrooms, and set property type to House (factor = 1). The calculation is:

  • Step 1: Multiply bathrooms by 8 → 2 × 8 = 16
  • Step 2: Multiply bedrooms by 4 → 3 × 4 = 12
  • Step 3: Add them → 16 + 12 = 28
  • Step 4: Multiply by type factor → 28 × 1 = 28 L/min

The calculator shows a required flow of 28 L/min. Since 28 is between 20 and 30, the recommended pipe size is 22 mm. If the same property were a flat, the flow would be 28 × 0.8 = 22.4 L/min, still requiring 22 mm pipe.

What Part G Actually Requires

Part G of the Building Regulations covers water efficiency and hot water safety in new dwellings in England. The relevant section, G3, states that a dwelling must have a wholesome water supply and that the flow rate at the kitchen sink must not be less than 8 litres per minute. The regulation also requires that the hot water system be designed to prevent scalding, with a maximum temperature of 48°C at the tap. The calculator above helps you check the flow requirement, but it does not cover the temperature or safety aspects. For a full Part G compliance check, you need to verify the water efficiency standard (125 litres per person per day) and the hot water storage requirements, which are separate calculations.

How to Choose the Right Pipe Size

Choosing the correct pipe size is critical for meeting the flow rate. Undersized pipes create excessive pressure loss, reducing flow at the tap. Oversized pipes waste money and can lead to stagnant water. Here is a practical guide:

  • 15 mm pipe – suitable for a single bathroom or a small flat with a flow demand up to about 20 L/min.
  • 22 mm pipe – for most houses with 2–3 bathrooms, flows up to 30 L/min.
  • 28 mm pipe – for larger houses with 4+ bathrooms or long pipe runs, flows above 30 L/min.

These sizes assume a typical mains pressure of 2–4 bar and a pipe run of less than 15 metres. For longer runs or lower pressure, you may need to go up a size. The calculator gives a starting point, but a qualified plumber should always verify the design using pressure drop calculations that account for pipe length, fittings, and the actual mains pressure.

Common Mistakes and Misconceptions

One common mistake is confusing flow rate with pressure. Flow rate is the volume of water delivered per minute (litres per minute), while pressure is the force pushing the water (bar). A high-pressure system can still have low flow if the pipe is too narrow. Another misconception is that the Part G calculator gives the exact pipe size required by law. In reality, Part G does not specify pipe sizes; it specifies a minimum flow rate at the outlet. The pipe size is a design decision based on the flow rate, pressure, and pipe length. Also, the formula used here is a simplification. The official method in Approved Document G uses a more complex calculation based on the number of outlets and the probability of simultaneous use, but the bathroom/bedroom formula is a common rule-of-thumb that gives a conservative estimate.

Limits of the Calculator

This calculator is a design aid, not a substitute for professional engineering. It does not account for:

  • Actual mains pressure and flow available at the property boundary
  • Pipe length and the number of elbows, tees, and valves
  • Pressure losses through water meters, stopcocks, and other fittings
  • Simultaneous demand from appliances like washing machines or irrigation systems
  • Hot water recirculation systems that add extra flow requirements

If you are designing a new build or renovation, you should measure the incoming mains flow and pressure, then use a pressure drop chart to size the pipework. The calculator is most useful for a quick sanity check during the early design stage.

Frequently Asked Questions

What is the minimum flow rate for a kitchen sink under Part G?

Part G requires a minimum flow rate of 8 litres per minute at the kitchen sink. This is the baseline for the whole dwelling; the calculator uses a higher figure for the whole house to account for other outlets.

Does Part G apply to existing homes?

No, Part G applies to new dwellings and material changes of use. Existing homes are not required to upgrade their pipework to meet Part G unless they are being substantially renovated. However, if you replace a hot water cylinder, the new system must still meet the scalding safety requirements.

Can I use the calculator for a commercial building?

No, this calculator is designed for dwellings only. Commercial buildings have different flow requirements, often based on the number of fixtures and the type of occupancy. Consult a building services engineer for commercial projects.

What if my mains pressure is very low?

If your incoming mains pressure is below 1 bar, you may need a booster pump or a gravity-fed system with a cold water tank. The calculator assumes a reasonable mains pressure; for low-pressure situations, you need a more detailed analysis.

Is 22 mm pipe always better than 15 mm?

Not necessarily. Larger pipe means more water in the pipe, which can lead to stagnant water if the flow is low. Also, larger pipe is more expensive and harder to install. The right size depends on the flow demand and the pressure available.

How do I measure the actual flow rate of my taps?

Use a bucket and a stopwatch. Open the tap fully and time how long it takes to fill a 10-litre bucket. Divide 10 by the time in minutes to get the flow rate in litres per minute. For example, if it takes 30 seconds (0.5 minutes), the flow is 10 / 0.5 = 20 L/min.

Related

Formula used
in baths | Number of bathrooms | - | 2 | 0 | 20
in beds | Number of bedrooms | - | 3 | 0 | 20
in type | Property type | House=1, Flat=0.8 | 1
out flow | Minimum flow rate | L/min | (baths * 8 + beds * 4) * type | 1
out pipe | Recommended pipe size | mm | 15 + (flow > 20 ? 7 : 0) + (flow > 30 ? 8 : 0) | 0