The Part G water efficiency calculator works out the estimated water consumption of a new dwelling in litres per person per day, based on the fittings you plan to install. You enter the flow rates or capacities of toilets, taps, showers, baths, and kitchen sinks, and the calculator returns a single figure that you compare against the 125 L/person/day building regulation limit. This article explains the calculation, gives a worked example, and covers the common pitfalls when using it.
Formula
The Part G water efficiency calculation is a weighted sum of the water use of each fitting, divided by the number of occupants (assumed to be 2.4 for a typical dwelling). The standard formula from the UK Building Regulations Approved Document G is:
Total consumption (L/person/day) = (WC × 4.4) + (Basin taps × 1.58 × 0.1 × 60) + (Showers × 0.05 × 60) + (Baths × 0.5) + (Kitchen sink × 0.44 × 0.1 × 60) + (Washing machine × 2.1)
Where:
- WC = full flush volume of the toilet (litres per flush). The 4.4 factor assumes 4.4 flushes per person per day.
- Basin taps = flow rate in litres per minute. The 1.58 factor is the assumed number of uses per person per day, and 0.1 is the average duration of each use in minutes (6 seconds). The ×60 converts the flow rate from L/min to L/hour.
- Showers = flow rate in litres per minute. The 0.05 factor is the assumed shower duration in hours (3 minutes) per person per day, and ×60 converts to litres per hour.
- Baths = capacity of the bath in litres to the overflow. The 0.5 factor assumes half a bath per person per day.
- Kitchen sink = flow rate in litres per minute. The 0.44 factor is the assumed number of uses per person per day, and 0.1 is the duration in minutes (6 seconds).
- Washing machine = water use in litres per kilogram of dry load. The 2.1 factor assumes 2.1 kg of dry laundry per person per day.
The result is the estimated daily water consumption per person. For a dwelling with more than 2.4 occupants, you can adjust the total by multiplying by 2.4 and dividing by the actual number of occupants, but the building regulations comparison is always against the 125 L/person/day limit.
Worked Example
Using the default values from the calculator above:
- WC flush volume = 6 L
- Basin taps flow rate = 6 L/min
- Shower flow rate = 9 L/min
- Bath capacity = 180 L
- Kitchen sink flow rate = 8 L/min
- Washing machine water use = 8.17 L/kg
Now apply the formula step by step:
- WC: 6 × 4.4 = 26.4 L/person/day
- Basin taps: 6 × 1.58 × 0.1 × 60 = 56.88 L/person/day
- Showers: 9 × 0.05 × 60 = 27.0 L/person/day
- Baths: 180 × 0.5 = 90.0 L/person/day
- Kitchen sink: 8 × 0.44 × 0.1 × 60 = 21.12 L/person/day
- Washing machine: 8.17 × 2.1 = 17.157 L/person/day
Total = 26.4 + 56.88 + 27.0 + 90.0 + 21.12 + 17.157 = 238.6 L/person/day
This is well above the 125 L/person/day limit, so you would need to choose more efficient fittings. For example, a 4.5 L flush toilet, 4 L/min taps, 8 L/min shower, and a smaller bath would bring the total down significantly.
Background: What Is Part G and Why Does It Matter?
Part G of the UK Building Regulations sets minimum standards for water efficiency in new dwellings. It requires that the estimated water consumption of a new home does not exceed 125 litres per person per day. This is a design target, not a measured value – you calculate it using the fittings you intend to install. The calculation is a standardised method that allows building control bodies to compare different designs fairly.
The 125 L/person/day figure is a national limit, but some local authorities have stricter local policies, often 110 L/person/day. Always check with your building control body or planning authority before submitting your design.
The calculation is based on assumptions about how often people use each fitting. These assumptions are fixed in the regulations, so you cannot change them to make your result look better. The only variables you control are the actual flow rates and capacities of the products you choose.
How the Calculator Works
The calculator uses the exact formula from Approved Document G. Each fitting type has a fixed usage pattern:
- Toilet: 4.4 flushes per person per day
- Basin taps: 1.58 uses per person per day, each lasting 6 seconds (0.1 minutes)
- Showers: 0.05 hours (3 minutes) per person per day
- Baths: 0.5 baths per person per day
- Kitchen sink: 0.44 uses per person per day, each lasting 6 seconds
- Washing machine: 2.1 kg of dry laundry per person per day
You enter the flow rate or capacity of each fitting, and the calculator multiplies by the usage factor to get the daily water use per person. The sum of all fittings is your total consumption.
Note that the formula assumes a fixed occupancy of 2.4 people per dwelling. If you know the actual number of occupants, you can scale the result, but the building regulations comparison is always based on 2.4.
How to Choose Fittings to Meet the 125 L Limit
To meet the 125 L/person/day target, you need to select fittings that are efficient but still practical. Here is a typical combination that meets the limit:
- Toilet: 4.5 L flush (dual flush with 3 L reduced flush)
- Basin taps: 4 L/min flow rate
- Shower: 8 L/min flow rate
- Bath: 150 L capacity
- Kitchen sink: 6 L/min flow rate
- Washing machine: 8 L/kg water use
Calculating this combination:
- WC: 4.5 × 4.4 = 19.8
- Basin taps: 4 × 1.58 × 0.1 × 60 = 37.92
- Showers: 8 × 0.05 × 60 = 24.0
- Baths: 150 × 0.5 = 75.0
- Kitchen sink: 6 × 0.44 × 0.1 × 60 = 15.84
- Washing machine: 8 × 2.1 = 16.8
Total = 19.8 + 37.92 + 24.0 + 75.0 + 15.84 + 16.8 = 189.36 L/person/day – still too high. The bath is the biggest contributor. Reducing the bath to 120 L gives 60 L, bringing the total to 174.36. To get under 125, you need a very efficient bath (or no bath at all), low-flow taps (3 L/min), and a shower at 6 L/min. A realistic compliant design might use:
- WC: 4.5 L
- Basin taps: 3 L/min
- Shower: 6 L/min
- Bath: 120 L
- Kitchen sink: 5 L/min
- Washing machine: 7 L/kg
Total = (4.5×4.4) + (3×1.58×0.1×60) + (6×0.05×60) + (120×0.5) + (5×0.44×0.1×60) + (7×2.1) = 19.8 + 28.44 + 18 + 60 + 13.2 + 14.7 = 154.14. Still above 125. The bath alone uses 60 L. If you remove the bath entirely, the total drops to 94.14 L, which is compliant. So for most homes, meeting Part G without a bath is much easier, but if you want a bath, you need to compensate with very low-flow taps and showerheads.
Common Mistakes and Misconceptions
One common mistake is using the wrong units. Flow rates for taps and showers are in litres per minute, but the formula uses hours for showers and minutes for taps. The calculator handles the conversion, but if you do it manually, be careful.
Another mistake is forgetting the washing machine. Many people only include the five main fittings (WC, basin, shower, bath, kitchen sink) and forget the washing machine, which adds about 15-20 L/person/day. This can push a borderline design over the limit.
A common misconception is that you can use the actual water usage of appliances instead of the fixed assumptions. For example, a washing machine that uses 6 L/kg is better than one that uses 10 L/kg, but the formula still uses the manufacturer’s declared water consumption per kilogram, not the actual usage.
Also, the bath capacity should be measured to the overflow, not the total volume of the bath. Many baths can hold more water than their nominal capacity, so check the manufacturer’s data.
Limitations of the Calculation
The Part G calculation is a design tool, not a prediction of actual water use. Real households vary widely – some people take long showers, others take baths, and laundry habits differ. The fixed assumptions are averages that may not reflect your specific household.
The calculation also ignores outdoor water use (gardens, car washing) and any greywater recycling or rainwater harvesting systems. If you install such systems, you may be able to reduce the calculated consumption, but the standard formula does not include them. You would need to use the more detailed methodology in the Water Efficiency Calculator for New Dwellings (WEC) to account for these.
Finally, the 125 L/person/day limit is based on a dwelling occupancy of 2.4 people. If your dwelling is designed for more or fewer occupants, the actual per-person consumption may differ, but the building regulations still use 2.4 for comparison.
Frequently Asked Questions
What is the difference between Part G and the Water Efficiency Calculator for New Dwellings (WEC)?
Part G is the building regulation that sets the 125 L/person/day limit. The WEC is the official spreadsheet tool that performs the calculation. The formula in this calculator is the same as the one in the WEC for the standard fittings. The WEC also allows you to add greywater and rainwater systems, which the simple formula does not.
Can I use this calculator for an existing home renovation?
Part G applies to new dwellings, not existing homes. However, if you are doing a material change of use (e.g., converting a barn to a house), the new dwelling must comply with Part G. For simple renovations, the water efficiency of existing fittings is not usually assessed.
What if my calculated value is above 125 L/person/day?
You will need to revise your design by choosing more efficient fittings. The easiest changes are to reduce the bath capacity (or remove the bath), install low-flow taps (3 L/min or less), and use a dual-flush toilet. You can also install a shower with a flow rate of 6 L/min or less. If you cannot meet the limit with standard fittings, you may need to consider greywater recycling or rainwater harvesting.
Does the calculator account for the number of bedrooms or occupants?
No, the standard Part G calculation assumes 2.4 occupants per dwelling, regardless of the number of bedrooms. The WEC has an optional calculation for actual occupancy if you know it, but the building regulations comparison is always against the 2.4-person assumption.
Are there local variations to the 125 L limit?
Yes, some local planning authorities have adopted stricter policies, often 110 L/person/day. You should check with your local building control body or planning portal to see if a stricter limit applies in your area. The calculator still works – just compare the result against the local limit.
Related
Formula used
in wc | WC flush volume | litres | 6 | 0 | 15 in tw | Taps (basins) flow rate | L/min | 6 | 0 | 30 in sw | Showers flow rate | L/min | 9 | 0 | 30 in bw | Bath capacity | litres | 180 | 0 | 400 in kw | Kitchen sink flow rate | L/min | 8 | 0 | 30 in nw | Washing machine water use | L/kg | 8.17 | 0 | 20 out cw | Total consumption | L/person/day | (wc*4.4 + tw*1.58*0.1*60 + sw*0.05*60 + bw*0.5 + kw*0.44*0.1*60 + nw*2.1) / 1 | 1
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.
More cards in this drawer
- Measuring Light Speed & Wavelength: How It Works
- Draco Race Blox Fruits: How to Get It
- ES File Explorer Tips & Tricks That Actually Work
- Remove Google FRP Lock on Oppo: Step-by-Step
- Forza Horizon 6: Unlock Legend Island & Earn Horizon Legend
- Clean Hair Dryer Filter: Improve Airflow