keepcalculator

06 Numbers and Powers

Greenhouse Temperature Calculator: How to Use It

Card No. 06·1271 · Updated · Standard formula, shown below

Temperature rise 34.62 °C
Internal temperature
49.62 °C
Result
Outside temperature
15 °C
You entered
Solar gain factor
500 W/m²
You entered
You enter
Outside temperature, Solar gain factor, Ventilation rate
You get
Temperature rise, Internal temperature
Rounding
2 dp

This calculator estimates the internal temperature of a greenhouse based on outside temperature, solar gain, and ventilation. You enter the outdoor temperature, the greenhouse’s solar heat gain factor, and the ventilation rate, and it returns the expected internal temperature rise and the final internal temperature. It is a simplified model that helps you understand the key drivers of greenhouse temperature before you invest in heating, cooling, or ventilation equipment.

Formula

The calculator uses a steady-state energy balance: heat gained from the sun equals heat lost through ventilation. The formula for the temperature rise is:

ΔT = (G × A × 0.9) / (V × ρ × cp × ACH)

Where:

  • ΔT = temperature rise inside the greenhouse (°C)
  • G = solar radiation on a horizontal surface (W/m²) – this is the solar gain factor you enter
  • A = floor area of the greenhouse (m²) – cancels out in the simplified formula
  • 0.9 = fraction of solar energy absorbed by the greenhouse (typical for glass or polycarbonate)
  • V = volume of the greenhouse (m³) – cancels out
  • ρ = density of air (about 1.2 kg/m³)
  • cp = specific heat of air (about 1000 J/(kg·K))
  • ACH = air changes per hour (ventilation rate)

Since A and V cancel out, the simplified formula becomes:

ΔT = (G × 0.9) / (ACH × 1300)

where 1300 = ρ × cp × (1 hour / 3600 seconds) × 1000 (to convert W to kW and hours to seconds). The result is in °C.

Worked Example

Using the default values: outside temperature = 15°C, solar gain = 500 W/m², ventilation = 10 air changes per hour.

  1. Calculate the numerator: 500 × 0.9 = 450
  2. Calculate the denominator: 10 × 1300 = 13000
  3. Divide: 450 / 13000 = 0.0346 (in kW·h/m³, but effectively °C per W/m²)
  4. Multiply by 1000 to get °C: 0.0346 × 1000 = 34.6°C

So the temperature rise is 34.6°C. Add the outside temperature: 15 + 34.6 = 49.6°C. That’s the internal temperature. This matches the calculator output (rounded to 2 decimals).

Why This Matters for Greenhouse Management

Greenhouses trap solar energy, which is great in winter but can be deadly in summer. Without proper ventilation, internal temperatures can soar 30–40°C above outside temperatures, even in moderate climates. This calculator helps you estimate the worst-case temperature rise so you can plan ventilation, shading, or cooling systems.

For example, on a sunny day with 800 W/m² solar radiation and only 5 air changes per hour (a fairly tight greenhouse), the temperature rise would be:

ΔT = (800 × 0.9) / (5 × 1300) × 1000 = 110.8°C

That’s obviously extreme – it shows that such a greenhouse would need much more ventilation or shading. In reality, plants transpire and the structure loses heat through conduction, so the actual rise would be lower, but the model still highlights the danger.

How to Choose Your Input Values

Getting accurate inputs is key to a useful estimate:

  • Outside temperature: Use the highest expected summer temperature for your region, or the average daily high for the season you’re planning for.
  • Solar gain factor: This is the solar radiation on a horizontal surface, typically 300–1000 W/m² depending on latitude, time of year, and cloud cover. Clear summer days in temperate regions often reach 800–1000 W/m² at noon. Use a weather station or solar radiation database for your location.
  • Ventilation rate: This is the number of times the greenhouse air is replaced per hour. Natural ventilation (roof and side vents) typically gives 10–30 air changes per hour. Forced ventilation (fans) can achieve 30–60. A tightly sealed greenhouse might have only 1–5.

If you’re unsure, try a range. For example, test with 10 and 20 air changes to see how much difference ventilation makes.

Common Mistakes and Limitations

This model is a simplification. It ignores:

  • Heat loss through the greenhouse cover (conduction and radiation) – this becomes significant at night or when the outside temperature is much lower than inside.
  • Evaporative cooling from plants (transpiration) – this can reduce temperature by 5–10°C in a well-watered greenhouse.
  • Thermal mass (floor, water barrels, etc.) – these absorb heat during the day and release it at night, smoothing out temperature swings.
  • Shading from nearby structures or trees.

Common mistakes when using the calculator:

  • Using the outside temperature at night instead of the daytime high – this overestimates the rise.
  • Forgetting that ventilation rate is per hour, not per minute.
  • Using a solar gain factor that’s too high for cloudy conditions.

The result is a worst-case estimate for a clear, sunny day. Real temperatures will be lower, but it’s better to plan for the worst.

Alternatives to This Model

If you need more accuracy, you can use:

  • Dynamic simulation software (e.g., greenhouse climate models) that account for hourly weather, cover materials, and plant growth.
  • Empirical charts from agricultural extension services that show temperature rise vs. ventilation rate for typical greenhouses.
  • Simple rules of thumb: For a well-ventilated greenhouse (20+ ACH), expect a rise of 5–10°C above outside on a sunny day. For a poorly ventilated one (5 ACH), expect 20–30°C.

This calculator is a quick educational tool, not a substitute for engineering design.

Safety and Practical Tips

High temperatures can damage or kill plants. Most crops suffer when temperatures exceed 30–35°C, and pollen viability drops above 35°C. To protect your plants:

  • Open vents and doors early in the morning before the temperature rises.
  • Use shade cloth (30–50% shade) during the hottest months.
  • Install exhaust fans with thermostats for automatic cooling.
  • Use evaporative cooling pads in dry climates – they can reduce temperature by 10–15°C.
  • Monitor temperature with a max-min thermometer or a digital sensor.

Never rely on a single calculation for critical decisions. Always verify with actual measurements and consult local horticultural experts for specific crop requirements.

Frequently Asked Questions

Q: What is the ideal temperature for a greenhouse?
A: It depends on the plants. Cool-season crops (lettuce, spinach) prefer 15–20°C; warm-season crops (tomatoes, peppers) prefer 20–30°C. Seedlings often need 20–25°C. Avoid extremes above 35°C or below 5°C for most plants.

Q: How many air changes per hour do I need for summer cooling?
A: For moderate climates, 20–30 air changes per hour is usually sufficient to keep the temperature rise below 10°C. In hot climates, you may need 40–60 ACH or evaporative cooling. Use the calculator to test different rates.

Q: Does the type of glazing matter?
A> Yes. The 0.9 factor assumes glass or polycarbonate that transmits about 90% of solar radiation. Double-layer polycarbonate transmits slightly less (80–85%), and dirty or aged glazing reduces transmission further. You can adjust the factor mentally – for 80% transmission, use 0.8 instead of 0.9.

Q: Why does my greenhouse get hotter than the calculator predicts?
A> The calculator assumes steady-state conditions and ignores heat storage. In reality, the greenhouse structure and floor absorb heat during the day, which can make the air temperature rise faster than the model. Also, if your ventilation is blocked or undersized, the actual ACH will be lower than you think.

Q: Can I use this for a cold frame or polytunnel?
A> Yes, the same principles apply. Cold frames are smaller and often have lower ventilation rates, so the temperature rise can be even higher. Polytunnels (hoop houses) are similar to greenhouses but may have less ventilation unless roll-up sides are used.

Q: What is the best way to measure solar radiation for the input?
A> A solar power meter (pyranometer) gives direct readings in W/m². If you don’t have one, use typical values: 1000 W/m² for bright midday sun in summer, 600–800 for hazy sun, 300–500 for overcast. Your local weather station may also report solar radiation.

Related

Formula used
in t_out | Outside temperature | °C | 15 | -40 | 50
in gain | Solar gain factor | W/m² | 500 | 0 | 1000
in vent | Ventilation rate | air changes per hour | 10 | 0 | 60
out temp_rise | Temperature rise | °C | (gain * 0.9) / (vent * 1300) * 1000 | 2
out t_in | Internal temperature | °C | t_out + (gain * 0.9) / (vent * 1300) * 1000 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.

More cards in this drawer

The whole Numbers and Powers drawer →