Colocation Provider Questions to Ask Before Signing

Card No. 06·72687 · Updated · Standard formula, shown below

Before you sign a colocation contract, you need to ask specific questions about power, cooling, connectivity, security, and the provider’s financial health. The answers determine whether your equipment stays online, stays safe, and stays within budget. This guide covers the essential questions to ask any potential data center colocation provider.

Why Colocation?

Colocation means renting space, power, and cooling for your servers in a third-party data center. You own the hardware but lease the facility. The main benefits are reliability, redundancy, and scalability that most offices cannot match. Data centers invest in backup power, multiple internet connections, and physical security that would be prohibitively expensive for a single company to build. Colocation also lets you expand capacity quickly by adding more racks or cabinets as your needs grow, without the long lead time of building out your own facility.

How Colocation Works

You typically rent a rack, a cage, or a private suite. The provider supplies the building, cooling, power distribution, and often the network backbone. You bring your own servers, storage, and sometimes your own network equipment. You manage your own hardware remotely or through remote hands services. The provider handles the facility infrastructure: generators, UPS systems, HVAC, fire suppression, and physical security. Your responsibility is the IT stack, from the operating system up. Service level agreements (SLAs) define uptime guarantees, response times, and penalties for failures.

Key Questions to Ask Before Choosing

Power and Cooling

  • What is the power density per rack? Most providers offer from 2 kW to 30 kW per rack. Know your current and future needs.
  • Is power billed as a flat rate or metered? Metered billing can be cheaper if your usage varies, but flat rates are predictable.
  • What is the redundancy of the UPS and generators? N+1 is common, but 2N is better for critical workloads. Ask about transfer times and whether they are tested regularly.
  • What cooling method is used? Air cooling is standard, but liquid cooling may be needed for high-density racks. Ask about the temperature and humidity range guaranteed in the SLA.
  • How long can the generators run on fuel? Typical is 24 to 48 hours, but ask about refueling contracts.

Connectivity and Network

  • How many internet service providers (ISPs) are in the building? More carriers mean more redundancy and competitive pricing.
  • Is cross-connect pricing included or extra? Cross-connects connect your rack to a carrier or another customer. Some providers include a few, others charge per port.
  • What is the average latency to major internet exchanges? If you serve a regional audience, proximity to an exchange matters.
  • Can you bring your own network equipment and carriers? Some facilities require you to use their approved list.

Physical Security

  • What security measures are in place? Look for 24/7 guards, biometric access, mantraps, and CCTV with retention policies.
  • How is visitor access controlled? Ask if visitors must be escorted and if there is a visitor log.
  • Is there a cage or cabinet lock option? You may want a lockable cage for compliance reasons.

Operations and Support

  • What are the remote hands services? If you are not local, you need staff to reboot servers, replace hardware, or run cables. Ask about response times and hourly rates.
  • What is the SLA for power and network uptime? 99.9% is common, but 99.99% is better. Read the SLA carefully for exclusions and credits.
  • How are maintenance windows communicated? You need advanced notice for planned maintenance that could affect your equipment.
  • What is the escalation procedure for incidents? Get a clear chain of command and contact numbers.

Costs and Contract Terms

Colocation pricing varies widely by region, power density, and services. Typical costs include a monthly fee for space and power, plus additional charges for bandwidth, cross-connects, remote hands, and storage. Some providers require a 12-month contract, others offer month-to-month at a premium. Ask about:

  • Setup fees: Are there one-time installation charges for cabling, power drops, or cage construction?
  • Bandwidth billing: Is it 95th percentile or flat? 95th percentile billing means you pay based on your peak usage, which can spike costs.
  • Overage charges: What happens if you exceed your contracted power or bandwidth? Rates can be steep.
  • Exit fees: Is there a cost to move out? Some contracts require notice periods and fees for decommissioning.
  • Price lock: Is the rate guaranteed for the term, or can it increase with notice?

Common Problems and How to Avoid Them

The most common colocation problems are power failures, network outages, and security breaches. Power failures often stem from inadequate generator testing or fuel supply issues. Ask about the provider’s maintenance schedule and whether they conduct load testing on generators. Network outages can occur if the facility has only one upstream provider or if the internal network is not redundant. Inquire about the diversity of fiber paths into the building. Security breaches are rare but can happen if physical access controls are weak. Look for a provider that follows industry standards like SOC 2 or ISO 27001 for their data center operations. Another common issue is poor remote hands support—slow response times can turn a minor issue into major downtime. Ask for references or case studies from other customers with similar setups.

Comparing Providers

When comparing colocation providers, create a weighted scorecard. List your requirements: power density, redundancy, carrier diversity, security, support, and budget. Visit the facilities in person if possible. Look at the cleanliness, the condition of the cabling, and the attitude of the staff. Check the building’s location: is it in a flood zone or earthquake-prone area? Ask about the building’s age and any past incidents. Also consider the provider’s financial stability; you do not want to be locked into a contract with a company that may go bankrupt. Publicly traded companies often provide more transparency, but private firms can be equally reliable. Read online reviews and talk to current customers if you can.

Alternatives to Colocation

Colocation is not the only option. You could use cloud services like AWS or Azure, which offer scalability without hardware ownership. The trade-off is ongoing costs and less control over hardware. You could also build your own data center, which gives full control but requires significant capital and expertise. For small workloads, a managed hosting provider might be simpler, but you lose the ability to manage your own hardware. Colocation sits between on-premise and cloud: you own the hardware but rent the facility. Choose colocation when you need high performance, low latency, and regulatory compliance, but do not want to build a data center.

Frequently Asked Questions

How much does colocation cost per month?

Costs vary widely, but a typical 1-2 kW rack with 1-2 Mbps of bandwidth might cost $500-$1,000 per month in a Tier 3 facility. Higher power densities, more bandwidth, and additional services like remote hands increase the price. Always get a detailed quote with all fees itemized.

What is the difference between Tier 3 and Tier 4 data centers?

Tier 3 provides N+1 redundancy for power and cooling, meaning there is a backup for each critical component, and allows for concurrent maintenance. Tier 4 provides 2N redundancy, meaning two independent power and cooling paths, and is designed to tolerate any single point of failure. Tier 4 is more expensive and is typically used for mission-critical applications.

Can I bring my own hardware to a colocation facility?

Yes, colocation is designed for you to bring your own servers, storage, and network gear. The provider supplies the facility infrastructure. You are responsible for installing and maintaining your hardware, either on-site or via remote hands.

How do I ensure my data is secure in a colocation facility?

Look for facilities with strong physical security, such as biometric access, 24/7 monitoring, and secure cages. Also ensure the provider has network security measures like firewalls and intrusion detection, and that you follow best practices for your own systems, such as encryption and access controls.

What happens if the data center loses power?

Most colocation facilities have UPS systems that provide immediate power during an outage, followed by diesel generators that kick in within seconds. Ask about the generator fuel capacity and refueling agreements. The SLA should guarantee uptime, but you should also have your own redundancy plan, such as multiple sites or cloud failover.

Can I upgrade my power or bandwidth later?

Yes, most providers allow you to increase power and bandwidth as your needs grow, but there may be additional costs or lead times. Ask about the flexibility of your contract and whether upgrades are subject to availability.